The 2020 J. S. Gravenstein Award for lifetime achievement in the area of technology in anesthesia will be presented to Dr. Kirk Shelley. He will be presenting a keynote talk at the 2020 STA Annual Meeting, at noon, January 17, 2020.  

The award is named for J. S. "Nik" Gravenstein, MD, a founding member and former president of the STA. For over thirty years, Dr. Gravenstein has been a driving force in advancing anesthesia technology, patient simulation and anesthesia patient safety. His lifelong commitment to developing and teaching anesthesia technology embodies the values of the Society.  Dr. Gravenstein passed away in 2009.


Read more about Dr. Shelley's contributions

A.        Personal Statement

As an ambulatory anesthesiologist, I am committed to the development of the best possible noninvasive clinical monitoring tools. My background is that of being a double boarded physician (Internal Medicine and Anesthesiology) with a PhD in biochemistry. I have been studying non-invasive cardiovascular waveforms for thirty years.  My focus has been on the photoplethysmographic and peripheral venous pressure waveform. The goal of this work has been to develop an understanding of the peripheral cardiovascular physiology.  The secondary goal has been utilization of this understanding to develop new methods of patient monitoring.  I believe that the state-of-the-art digital signal processing methods combined with new understandings of cardiovascular physiology will allow for significant breakthroughs in this field. 

B.        Positions and Honors

2008-now        Professor of Anesthesiology, Yale University - Chief of Ambulatory Anesthesia

1999-2008       Associate Professor of Anesthesiology, Yale University - Chief of Outpatient

1997-1999       Assistant Professor of Anesthesiology, Yale University, CT

1992-1997       Assistant Professor of Anesthesiology, Hershey Medical Center, PSU, PA

1984-1989       Chief of Medical Services, Sheppard Regional Hospital, Sheppard AFB, TX

 

1993    1st Prize for Best Scientific Exhibit – Anesthesia Patient Safety Foundation

1994    1st Prize for Best Exhibit - American Society of Anesthesiologists

1997    1st Prize for Best Abstract from the Society for Technology in Anesthesia

2001    1st Prize for Best Technology Abstract from the Society for Technology in Anesthesia

2011    President of the Society for Technology in Anesthesia

2012    The Harvey W. Wiley Lifetime Achievement Award - IAMPOV

 

Member:  IEEE Engineering in Medicine and Biology Society, Biomedical Engineering Society

C. Contribution to Science

The main thrust of my work has involved pulse oximetry technology. The pulse oximeter is the most commonly used clinical monitor in the healthcare system.  The photoplethysmographic (PPG) waveform is at the core of pulse oximeter technology. I have worked to expand the understanding and use of this noninvasive cardiopulmonary waveform.  Some of my most cited papers are educational and provocative in nature.  They challenge the reader to re-examine this ubiquitous wave for features beyond its primary use of oxygen saturation measurement.  These papers point out that the PPG contains information regarding the cardiovascular, pulmonary and autonomic systems. [1-4]

1.         Shelley, K.H., Photoplethysmography: Beyond The Calculation Of Arterial Oxygen Saturation And Heart Rate. Anesth Analg, 2007. 105(6 Suppl): p. S31-6.

2.         Shelley, K.H. and S. Shelley, Pulse Oximeter Waveform: Photoelectric Plethysmography, in Clinical Monitoring: Practical Applications for Anesthesia and Critical Care, C.L. Lake, R.L. Hines, and C.D. Blitt, Editors. 2001, W.B. Saunders Company: Philadelphia PA. p. 420-428.

3.         Alian, A.A. and K.H. Shelley, Photoplethysmography. Best Pract Res Clin Anaesthesiol, 2014. 28(4): p. 395-406.

4.         Alian, A.A. and K.H. Shelley, Photoplethysmography: Analysis of the pulse oximeter waveform, in Monitoring Technologies In Acute Care Environments, J.M. Ehrenfeld and M. Cannesson, Editors. 2014, Springer New York. p. 165-178.

In the process of studying the pulse oximeter waveform (PPG) I have discovered a number of unanticipated features.  These have included the impact of peripheral venous blood on the waveform. This has allowed for the explanation of device artifact as well the calculation of new clinical parameters.  Most notably, this research is the key component of a new monitoring technique that my laboratory developed for the detection of blood loss during pediatric cases. (1-4)

1.         Shelley KH, Dickstein M, Shulman SM. The detection of peripheral venous pulsation using the pulse oximeter as a plethysmograph. J Clin Monit 1993;9:283-7.

2.         Shelley K, Tamai D, Jablonka D, Gesquiere M, Stout R, Silverman D. The effect of venous pulsation on the forehead pulse oximeter wave form as a possible source of error in SPo2 calculation. Anesth Analg 2005;100:743-7.

3.         Walton ZD, Kyriacou PA, Silverman DG, Shelley KH. Measuring venous oxygenation using the photoplethysmograph waveform. J Clin Monit Comput 2010;24:295-303.

4.         Alian AA, Atteya G, Gaal D, Golembeski T, Smith BG, Dai F, Silverman DG, Shelley K. Ventilation-Induced Modulation of Pulse Oximeter Waveforms: A Method for the Assessment of Early Changes in Intravascular Volume During Spinal Fusion Surgery in Pediatric Patients. Anesth Analg 2016;123:346-56.

The photoplethysmographic (PPG) waveform is created by the interaction of the cardiac, pulmonary and autonomic systems.  By studying this interaction, one can gain clues as to a patient’s condition as well as ways of optimizing it via therapeutic interventions. One of the earliest observations was the impact of ventilation on the PPG waveform.  Through my research, it was discovered that both cardiac output (stroke volume) and pre-load (venous) blood are modulated.  These modulations can be identified and quantified.  Through optimization of these parameters it was found that they could be used to guide IV fluid therapy during hypovolemia. (1-4)

1.         Shelley KH, Awad AA, Stout RG, Silverman DG. The use of joint time frequency analysis to quantify the effect of ventilation on the pulse oximeter waveform. J Clin Monit Comput 2006;20:81-7.

2.         Shelley KH, Jablonka DH, Awad AA, Stout RG, Rezkanna H, Silverman DG. What is the best site for measuring the effect of ventilation on the pulse oximeter waveform? Anesth Analg 2006;103:372-7.

3.         Alian AA, Galante NJ, Stachenfeld NS, Silverman DG, Shelley KH. Impact of central hypovolemia on photoplethysmographic waveform parameters in healthy volunteers part 2: frequency domain analysis. J Clin Monit Comput 2011;25:387-96.

4.         Scully CG, Selvaraj N, Romberg FW, Wardhan R, Ryan J, Florian JP, Silverman DG, Shelley KH, Chon KH. Using time-frequency analysis of the photoplethysmographic waveform to detect the withdrawal of 900 mL of blood. Anesth Analg 2012;115:74-81.